Upgrade by running the newer installer over the existing installation. You do not need to uninstall first.
What the installer preserves
- Configuration.
config.yamlfiles under%ProgramData%\Flux Inc\DICOM7\are only created when missing. Your edited configuration is never overwritten. - Templates, cache, and logs under
%ProgramData%\Flux Inc\DICOM7\are not touched. - Service accounts of
DICOM7_ORU2REPORTandDICOM7_HL72HL7. These two services are only registered when they do not exist yet, so a logon account you configured is kept.
What the installer changes
- Program files in the installation folder are replaced.
- Before replacing files, the suite installer stops every running
DICOM7_*service and waits up to 30 seconds for each to stop. If a service does not stop, the installer restarts the services it stopped and cancels the upgrade. DICOM7_DICOM2ORM,DICOM7_DICOM2ORU,DICOM7_ORM2DICOM, andDICOM7_ORU2DICOMare removed and registered again, then started. A custom logon account or startup type on these four services must be set again after the upgrade.- When it finishes, the installer restarts the services that were running before the upgrade. An HL72HL7 service that was stopped before the upgrade stays stopped.
Recommended procedure
- Read the release notes for configuration changes that apply to your version.
- Back up
%ProgramData%\Flux Inc\DICOM7\(configuration and templates at least). - Note the logon account and startup type of each
DICOM7_*service inservices.msc. - Check that no service has a long backlog in its cache. See Cache and Retention.
- Run the new installer as an administrator, selecting the same components as before.
- Restore any service account settings the installer reset.
- Check each service log for a clean start. See Starting and Stopping the Services.
New settings
A new version can add configuration settings. Because your existing config.yaml is kept, new settings take their built-in defaults until you add them. Compare your file with the reference on the service's configuration page.
Upgrading HL72HL7
The standalone HL72HL7 installer:
- stops
DICOM7_HL72HL7if it is running and waits for it to stop; if it does not stop, no files are replaced, - replaces the program files,
- re-applies the access restrictions on the data folder (
SYSTEMandAdministratorsonly), - validates the existing
config.yamlwith the new version and stops the upgrade if it is not valid, - re-registers the service only if it was registered from a different installation folder,
- starts the service if it was running before the upgrade.
Records captured by an earlier HL72HL7 version are read and delivered by the new version. See HL72HL7 for version-specific settings.
Downgrading
Uninstall the current version, then install the older version. Your configuration and cache are kept. A configuration file that contains settings the older version does not know will not load: HL72HL7 refuses to start, and the other services ignore the whole file and start with built-in defaults. Remove the newer settings before downgrading.