Upgrading ​

Upgrade by running the newer installer over the existing installation. You do not need to uninstall first.

What the installer preserves ​

  • Configuration. config.yaml files under %ProgramData%\Flux Inc\DICOM7\ are only created when missing. Your edited configuration is never overwritten.
  • Templates, cache, and logs under %ProgramData%\Flux Inc\DICOM7\ are not touched.
  • Service accounts of DICOM7_ORU2REPORT and DICOM7_HL72HL7. These two services are only registered when they do not exist yet, so a logon account you configured is kept.

What the installer changes ​

  • Program files in the installation folder are replaced.
  • Before replacing files, the suite installer stops every running DICOM7_* service and waits up to 30 seconds for each to stop. If a service does not stop, the installer restarts the services it stopped and cancels the upgrade.
  • DICOM7_DICOM2ORM, DICOM7_DICOM2ORU, DICOM7_ORM2DICOM, and DICOM7_ORU2DICOM are removed and registered again, then started. A custom logon account or startup type on these four services must be set again after the upgrade.
  • When it finishes, the installer restarts the services that were running before the upgrade. An HL72HL7 service that was stopped before the upgrade stays stopped.
  1. Read the release notes for configuration changes that apply to your version.
  2. Back up %ProgramData%\Flux Inc\DICOM7\ (configuration and templates at least).
  3. Note the logon account and startup type of each DICOM7_* service in services.msc.
  4. Check that no service has a long backlog in its cache. See Cache and Retention.
  5. Run the new installer as an administrator, selecting the same components as before.
  6. Restore any service account settings the installer reset.
  7. Check each service log for a clean start. See Starting and Stopping the Services.

New settings

A new version can add configuration settings. Because your existing config.yaml is kept, new settings take their built-in defaults until you add them. Compare your file with the reference on the service's configuration page.

Upgrading HL72HL7 ​

The standalone HL72HL7 installer:

  • stops DICOM7_HL72HL7 if it is running and waits for it to stop; if it does not stop, no files are replaced,
  • replaces the program files,
  • re-applies the access restrictions on the data folder (SYSTEM and Administrators only),
  • validates the existing config.yaml with the new version and stops the upgrade if it is not valid,
  • re-registers the service only if it was registered from a different installation folder,
  • starts the service if it was running before the upgrade.

Records captured by an earlier HL72HL7 version are read and delivered by the new version. See HL72HL7 for version-specific settings.

Downgrading ​

Uninstall the current version, then install the older version. Your configuration and cache are kept. A configuration file that contains settings the older version does not know will not load: HL72HL7 refuses to start, and the other services ignore the whole file and start with built-in defaults. Remove the newer settings before downgrading.