Appearance
Installing DICOM7
Prerequisites
- 64-bit Windows
- .NET Framework 4.6.2 or later
- Administrator rights
- Network access between the host and the DICOM and HL7 systems you are connecting, on the ports you configure
- For ORU2REPORT only: Microsoft Edge or Google Chrome
Installers
DICOM7 is distributed as two Windows installers:
| Installer | Contents |
|---|---|
DICOM7Setup-x64-<version>.exe | The DICOM7 suite. Lets you choose which services to install. |
DICOM7-HL72HL7-Setup-x64-<version>.exe | A standalone installer for the HL72HL7 broker only. |
Contact Flux support to obtain the installer for your license.
Installing the suite
Run
DICOM7Setup-x64-<version>.exeas an administrator.Read the information page, then choose the installation folder (default
C:\Program Files\Flux Inc\DICOM7).Choose the components to install:
Component Installed by Full Windows service Core Files (required) Yes — DICOM2ORM — DICOM Worklist to HL7 ORM Yes DICOM7_DICOM2ORMDICOM2ORU — DICOM C-STORE to HL7 ORU Yes DICOM7_DICOM2ORUORM2DICOM — HL7 ORM to DICOM Modality Worklist Yes DICOM7_ORM2DICOMORU2DICOM — HL7 ORU to DICOM C-STORE Yes DICOM7_ORU2DICOMORU2REPORT — HL7 ORU to PDF/HTML reports Yes DICOM7_ORU2REPORTHL72HL7 — HL7-to-HL7 broker No (choose Custom) DICOM7_HL72HL7Finish the wizard. For each selected component the installer:
- copies the program files to the installation folder,
- creates
%ProgramData%\Flux Inc\DICOM7\<SERVICE>\config.yamlfrom the default configuration only if it does not already exist, - registers the Windows service and starts it.
Install only what you need
The default HL7 listener port of ORM2DICOM, ORU2DICOM, and HL72HL7 is 7777. If you install more than one of them on the same host, give each its own HL7.ListenPort before starting them, otherwise only the first one to start can listen. See Troubleshooting.
The services start with the default configuration. Its hosts, ports, and AE titles are examples, not the endpoints agreed for your site. Configure each service, then restart it. See Configuration and Starting and Stopping the Services.
Installing the HL72HL7 broker on its own
- Run
DICOM7-HL72HL7-Setup-x64-<version>.exeas an administrator. - Choose the installation folder (default
C:\Program Files\Flux Inc\DICOM7 HL72HL7 Broker). - The installer:
- copies the program files,
- creates
%ProgramData%\Flux Inc\DICOM7\HL72HL7\config.yamlonly if it does not already exist, - restricts the data folder to
SYSTEMand the localAdministratorsgroup, - validates the configuration with
HL72HL7.exe --validate-configand stops the installation if it is invalid, - registers the
DICOM7_HL72HL7service and starts it.
A new HL72HL7 installation starts in CaptureOnly mode: it accepts and stores the allowed message types but does not forward them until you configure destinations. See HL72HL7.
Upgrading from ORM2HL7
The HL72HL7 installer replaces the older ORM2HL7 broker. When it finds the DICOM7_ORM2HL7 service it stops and removes it, removes the old program files, and installs HL72HL7 in its own folder. Configuration and cached data under %ProgramData% are not removed.
Default directories
| Purpose | Path |
|---|---|
| Program files (suite) | C:\Program Files\Flux Inc\DICOM7\ |
| Program files (standalone HL72HL7) | C:\Program Files\Flux Inc\DICOM7 HL72HL7 Broker\ |
| Configuration | %ProgramData%\Flux Inc\DICOM7\<SERVICE>\config.yaml |
| Cache | %ProgramData%\Flux Inc\DICOM7\<SERVICE>\cache\ (configurable) |
| Logs | %ProgramData%\Flux Inc\DICOM7\<SERVICE>\logs\ |
| HL7 and report templates | %ProgramData%\Flux Inc\DICOM7\<SERVICE>\ |
%ProgramData% is normally C:\ProgramData.
Service account
The services are registered to run as the Local System account and to start automatically with Windows. If a Windows service stops unexpectedly, Windows restarts it after 10 seconds, then after 20 seconds on a second failure.
ORU2REPORT launches a browser to render reports. Some browser installations do not render reliably under Local System. For a new ORU2REPORT installation, consider running DICOM7_ORU2REPORT under a dedicated, non-expiring account that can start the browser, and grant that account Modify access to C:\ProgramData\Flux Inc\DICOM7\ORU2REPORT. Upgrades keep the account you configured.
Verifying the installation
- Open
services.mscand confirm each installedDICOM7_*service is Running. - Open the service log in
%ProgramData%\Flux Inc\DICOM7\<SERVICE>\logs\and confirm that it reports the configuration it loaded and the ports it is listening on. See Interrogating the Logs.