Skip to content

Licensing and Activation ​

DICOM Printer 2 uses a license-based activation system to enable full functionality.

License System Overview ​

DICOM Printer 2 requires a valid license to operate. The licensing system uses:

  • Request Code - Unique code generated from your system
  • Activation Code - License key provided by Flux Inc
  • Validity Period - Duration for which the license is valid

License States ​

Unlicensed ​

The software is installed but not activated.

Behavior:

  • Service runs in trial or limited mode
  • May have feature restrictions or time limitations
  • Displays warnings about unlicensed state

Active ​

The software is properly licensed and activated.

Behavior:

  • Full functionality enabled
  • No restrictions or warnings
  • Valid until expiration date

Expired ​

The license validity period has ended.

Behavior:

  • Similar to unlicensed state
  • Service may stop processing
  • Requires license renewal

Invalid ​

The activation code is invalid or corrupted.

Behavior:

  • Service fails to start
  • Error messages in logs
  • Requires valid activation code

Activation Process ​

Method 1: Using the DICOM Printer Console ​

  1. Launch the Console

    Start Menu → Flux Inc → DICOM Printer 2 → DICOM Printer Console
  2. Open Manage → Activate Click the gear icon in the top bar to open Manage, then click Activate. The Console resolves the installed activator via /api/admin/activate-info and launches it.

  3. Complete activation in the wizard The activator opens the activation page in the default web browser, displays the hardware request code, and polls the licensing server in the background until activation succeeds.

  4. Verify activation The Console Manage pane reflects the new licensed state once the activator reports success.

Method 2: Using Command Line ​

  1. Launch the interactive activation wizard

    cmd
    cd "C:\Program Files (x86)\Flux Inc\DICOM Printer 2"
    DicomPrinter.exe --activate

    The wizard opens the activation page in the default browser, displays the request code, and polls until activation completes. Requires an interactive console session (not Session 0).

  2. Inspect current activation data

    cmd
    DicomPrinter.exe --activation-data

    Emits an XML document containing the hardware RequestCode and the stored ActivationCode.

  3. Print the machine-specific activation URL

    cmd
    DicomPrinter.exe --get-activation-url

    Outputs a URL like https://store.fluxinc.ca/activate?request=... that you can paste into a browser on another machine to complete activation.

  4. Complete activation offline On a machine without internet access, use DicomPrinter.exe --get-activation-url to obtain the machine-specific activation URL, open it in a browser on another machine to retrieve the activation code, then run DicomPrinter.exe --activate and supply that code. The activation code is written to the .activation file in the same directory as config.xml; you do not hand-edit config.xml to license the product.

Activation Code Format ​

Activation codes are formatted as:

XXXX-XXXX-XXXX-XXXX-XXXX-XXXX-XXXX-XXXX

Important:

  • Activation codes are case-insensitive
  • Include all dashes when entering
  • Copy and paste to avoid typos
  • One activation code per installation

License Validity ​

Checking Expiration ​

DICOM Printer Console:

Manage → Activate (shows current activation state and days remaining)

Service Logs:

License valid for 123 days

Renewal ​

Before license expires:

  1. Contact Flux Inc for renewal
  2. Receive new activation code
  3. Enter new activation code (same process as initial activation)
  4. Validity period is extended

Request Code Generation ​

Request codes are generated from:

  • System hardware identifiers
  • MAC addresses
  • Disk serial numbers
  • Other system-specific data

Important:

  • Request code changes if hardware changes significantly
  • Same request code for same system
  • Re-activation required after major hardware changes

Where the Activation Code Is Stored ​

You do not hand-edit config.xml to license the product. When activation succeeds, the app stores the activation code in a file named .activation, located in the same directory as config.xml.

Location: %ProgramData%\Flux Inc\DICOM Printer 2\config\.activation (alongside %ProgramData%\Flux Inc\DICOM Printer 2\config\config.xml)

The activation code is not stored in the Windows registry, and it is not placed into config.xml.

Note: A <RegistrationKey> element may appear inside config.xml. It is inert and ignored — it plays no part in current activation. Editing or removing it has no effect on licensing.

Troubleshooting ​

Invalid Activation Code ​

Symptoms:

  • Error: "Invalid activation code"
  • License state remains unlicensed

Causes:

  • Typo in activation code
  • Wrong activation code for this system
  • Corrupted activation code

Solutions:

  • Double-check activation code
  • Copy and paste instead of manual entry
  • Regenerate request code and get new activation code
  • Contact Flux Inc support

License Expired ​

Symptoms:

  • Service stops processing
  • Warning: "License expired"
  • License state shows as expired

Solutions:

  • Contact Flux Inc for license renewal
  • Enter new activation code
  • Restart service

Request Code Changed ​

Symptoms:

  • Previously activated system now shows as unlicensed
  • Error: "License invalid for this system"

Causes:

  • Significant hardware changes
  • System reinstallation
  • Virtual machine migration

Solutions:

  • Generate new request code
  • Contact Flux Inc with:
    • Old activation code
    • New request code
    • Explanation of change
  • Receive new activation code for new configuration

Service Won't Start with Invalid License ​

Symptoms:

  • Service fails to start
  • Error in logs: "License check failed"

Solutions:

  • Re-run activation (DicomPrinter.exe --activate) to obtain a fresh activation code
  • Inspect the stored activation with DicomPrinter.exe --activation-data
  • If the .activation file is corrupted, delete it (it sits next to config.xml) to fall back to trial mode, then re-activate
  • Contact Flux Inc for a valid activation code

License Management Best Practices ​

  1. Record activation codes - Store activation codes securely
  2. Monitor expiration - Set reminders before licenses expire
  3. Plan for renewal - Contact Flux Inc well before expiration
  4. Backup the .activation file - Keep a backup of the activated .activation file (stored next to config.xml)
  5. Document hardware - Record hardware configuration for reference
  6. Test after hardware changes - Verify licensing after system changes

Activation Support ​

For activation assistance:

Email: support@fluxinc.ca

Include:

  • Request code
  • Description of issue
  • DICOM Printer 2 version
  • Error messages (if any)

Response Time:

  • Typically within 1 business day
  • Expedited support available

License Types ​

Flux Inc offers various license types:

  • Standard - Single installation, annual renewal
  • Multi-site - Multiple installations, volume pricing
  • Enterprise - Site license with special terms
  • Development - For testing and development purposes

Contact Flux Inc for licensing options and pricing.